{"id":57,"date":"2015-05-29T19:33:16","date_gmt":"2015-05-29T19:33:16","guid":{"rendered":"http:\/\/jwst.astro.umontreal.ca\/?page_id=57"},"modified":"2017-02-13T15:09:37","modified_gmt":"2017-02-13T15:09:37","slug":"ami-performance","status":"publish","type":"page","link":"https:\/\/jwst.astro.umontreal.ca\/?page_id=57","title":{"rendered":"AMI"},"content":{"rendered":"<p><strong>Summary<\/strong><\/p>\n<p><strong><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-566 alignright\" src=\"http:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_contrast-1024x512.png\" alt=\"ami_contrast\" width=\"550\" height=\"275\" srcset=\"https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_contrast-1024x512.png 1024w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_contrast-300x150.png 300w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_contrast-768x384.png 768w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_contrast.png 1350w\" sizes=\"auto, (max-width: 550px) 100vw, 550px\" \/><\/strong><br \/>\nThe Aperture Masking\u00a0Interferometry (AMI) mode uses a Non-Redundant Mask (NRM) in the pupil plane in conjunction with one filter (F277W, F380M, F430M, F480M) to produce an interferogram on the detector that enables better spatial resolving power than the canonical ~lambda\/D limit for clear apertures. The NRM is composed of 7 hexagonal holes that span 21 non-redundant interferometric baselines. Careful analysis and modelisation of the astrophysical scene are required to extract the information. That way, the AMI\u00a0mode explores smaller inner working angles (0.1-0.4 arc seconds) than is possible with other JWST instruments, albeit at smaller contrasts of 8-9 magnitudes. \u00a0The added resolving power comes with smaller throughput (the mask admits 15% of the light that makes it to the pupil) so that 1h of integration time on a F480M=8\/10\/15 mag will achieve a contrast of about 7.0\/5.5\/3.0 magnitudes.\u00a0Stars as bright as F480M=3 can be observed.<br \/>\n<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-564 aligncenter\" src=\"http:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_concept-1024x394.png\" alt=\"ami_concept\" width=\"800\" height=\"308\" srcset=\"https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_concept-1024x394.png 1024w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_concept-300x115.png 300w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_concept-768x295.png 768w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_concept.png 1950w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/p>\n<p><strong>Operations C<img loading=\"lazy\" decoding=\"async\" class=\"wp-image-569 size-large alignright\" src=\"http:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_psf-1024x683.png\" alt=\"ami_psf\" width=\"640\" height=\"427\" srcset=\"https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_psf-1024x683.png 1024w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_psf-300x200.png 300w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_psf-768x512.png 768w, https:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/ami_psf.png 1350w\" sizes=\"auto, (max-width: 640px) 100vw, 640px\" \/>oncept<\/strong><\/p>\n<p>Target acquisition uses the F480M filter either crossed with the NRM pupil (for bright targets) or not (for faint targets). A center-of-light centroid is measured and used to fine-tune the target position within the 80&#215;80 sub-array (only once) then the Pupil Wheel is set to NRM and the Filter Wheel is set to the proper filter and observations can start. \u00a0There is possibility to dither to 4 different positions and micro-dither within each dither to 1, 9 or 25 sub positions. However, the best practice currently advocated is to neither dither nor sub-dither but simply stare at a fixed position. For high-contrast observations of dmag&gt;6-7, it is advised to observe a calibrator star within the same telescope visit to calibrate out the systematic wavefront error. Observations consist in a single exposure (if staring) composed of many (hundreds of) integrations, each with a large Ngroup (reads) enough to fill the full well depth. Ngroup may be as small as 2 for particularly bright targets. As an option during target acquisition, a CLEAR image (no NRM) may be obtained to calibrate the scene or to allow absolute flux calibration.<\/p>\n<p><strong>Readout Modes and\u00a0Saturation Limiting Magnitudes<\/strong><\/p>\n<p>Two readout modes are currently defined for AMI. Most of the observations will use the 80&#215;80 sub-array mode. Fainter targets could conceivably be observed in full-frame mode and still be efficient. The table below gives the saturation limiting magnitudes (Vega) for the four filters.<\/p>\n\n<table id=\"tablepress-5\" class=\"tablepress tablepress-id-5 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Filter<\/th><th class=\"column-2\">Readout<\/th><th class=\"column-3\">Saturation Limiting Magnitude<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">F277W<\/td><td class=\"column-2\">80x80<\/td><td class=\"column-3\">5.68<br \/>\n<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">F380M<\/td><td class=\"column-2\">80x80<\/td><td class=\"column-3\">3.33<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">F430M<\/td><td class=\"column-2\">80x80<\/td><td class=\"column-3\">2.85<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">F480M<\/td><td class=\"column-2\">80x80<\/td><td class=\"column-3\">2.74<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td colspan=\"2\" class=\"column-1\">* Tframe = 0.0745 sec, Ngroup = 2, Saturation = 50000 e-<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">F277W<\/td><td class=\"column-2\">2048x2048<\/td><td class=\"column-3\">10.08<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">F380M<\/td><td class=\"column-2\">2048x2048<\/td><td class=\"column-3\">8.73<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">F430M<\/td><td class=\"column-2\">2048x2048<\/td><td class=\"column-3\">8.25<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">F480M<\/td><td class=\"column-2\">2048x2048<\/td><td class=\"column-3\">8.14<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td colspan=\"2\" class=\"column-1\">* Tframe = 10.7 sec, Ngroup = 2, Saturation = 50000 e-<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n\n<p><strong>Simulator and Achievable Contrasts<\/strong><\/p>\n<p>Extracting information from AMI observations requires a modelling effort and a detailed analysis. Two approaches are studied: one in the Fourier space, one in the image plane. A paper led by Alexandra Greenbaum: &#8220;<em><a href=\"http:\/\/jwst.astro.umontreal.ca\/wp-content\/uploads\/Greenbaum_2015_ApJ_798_68.pdf\">AN IMAGE-PLANE ALGORITHM FOR JWST\u2019S NON-REDUNDANT APERTURE MASK DATA<\/a><\/em>&#8221; details the latter approach. The former approach is used for the\u00a0<a href=\"http:\/\/maestria.astro.umontreal.ca\/niriss\/AMIcontrast\/index.php\">AMI constrast simulator<\/a>\u00a0hosted at UdeM.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Summary The Aperture Masking\u00a0Interferometry (AMI) mode uses a Non-Redundant Mask (NRM) in the pupil plane in conjunction with one filter (F277W, F380M, F430M, F480M) to produce an interferogram on the detector that enables better spatial resolving power than&#8230; <a class=\"read-more\" href=\"https:\/\/jwst.astro.umontreal.ca\/?page_id=57\">Read More<\/a><\/p>\n","protected":false},"author":3,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"template-full.php","meta":{"footnotes":""},"class_list":["post-57","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/pages\/57","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=57"}],"version-history":[{"count":25,"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/pages\/57\/revisions"}],"predecessor-version":[{"id":659,"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=\/wp\/v2\/pages\/57\/revisions\/659"}],"wp:attachment":[{"href":"https:\/\/jwst.astro.umontreal.ca\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=57"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}